CVE-1999-1513
HighExploitation Probability (EPSS)
Elevated risk63th percentile - higher than 63% of all known CVEs
Summary
The management information base (MIB) for a 3Com SuperStack II hub running software version 2.10 contains an object identifier that is accessible by a read-only community string but lists the entire table of community strings.
Risk Assessment
This could allow attackers to conduct unauthorized activities, posing a significant security risk to the system.
Recommendation
It is recommended to update the software to the latest version and restrict access to the MIB to trusted users.
Related vulnerabilities
- CVE-2026-28336Critical
SolarWinds Dameware is affected by a command injection vulnerability that could lead to compromise of the remotely controlled host. Authentication is required.
- CVE-2026-109593Critical
An unauthenticated attacker with network access to SonicWall GMS 9.5.2 and earlier may be able to read internal GMS files, potentially exposing sensitive information.
- CVE-2026-121260Critical
Ziroom ZHOME A0101 1.0.1.0 Build 202004151405 contains a flaw in the loadstring function of usr/lib/lua/luci/controller/api/zrUsb.lua (Lua Handler component). The manipulation causes code injection and can be exploited remotely. The exploit has been published and may be used; the vendor did not respond to the disclosure.
- CVE-2026-118527MediumActively exploited
Use of predictable filenames in Ivanti Connect Secure before versions 25.1.1.3 and 22.8R2.6 allows a remote authenticated attacker to upload files with attacker-controlled content to a known location on disk.
- CVE-2026-89292Critical
In Eclipse Mnestix Browser versions 1.6.0 up to but excluding 2.3.0, an unauthenticated attacker could exfiltrate the MNESTIX_BACKEND_API_KEY for all configured Infrastructures.
- CVE-2026-4052Critical
This issue only impacts deployments where WSO2 Identity Server is configured as a Resident Key Manager with database sharing. In such environments, a self-registered user may gain access to the System REST APIs of WSO2 API Manager by obtaining a token from the WSO2 Identity Server token endpoint.
- CVE-2026-13594Critical
Zoho Corporation's ManageEngine Log360 and EventLog Analyzer versions 13062 and below are vulnerable to an issue that could allow an adversary to gain unauthorized access to the product.
- CVE-2026-120534Critical
The Advanced Custom Fields: Extended PRO plugin for WordPress is vulnerable to Limited Code Injection in all versions up to, and including, 0.9.2.6 via the render_field function. Insufficient validation of form configuration parameters allows unauthenticated attackers to call arbitrary WordPress functions with controlled arguments.
- CVE-2026-120518Critical
The BuddyPress XProfile Image Field plugin for WordPress is vulnerable to arbitrary file deletion in all versions up to, and including, 3.1.0. The bpxp_image_field_update_on_user_activation() function calls unlink() on a path built from visitor-supplied signup metadata without realpath() resolution, containment check, or extension allow-list.
- CVE-2026-86596Critical
The s2Member plugin for WordPress in versions up to and including 260927 is vulnerable to Remote Code Execution via the 'item_name' parameter. Insufficient sanitization in strip_php_tags_deep() only strips literal '<?' sequences, and a post-interpolation placeholder cleanup reassembles a valid '<?php' opener after the attacker-controlled value has already been embedded in the email template.
Original NVD description (English source)
Management information base (MIB) for a 3Com SuperStack II hub running software version 2.10 contains an object identifier (.1.3.6.1.4.1.43.10.4.2) that is accessible by a read-only community string, but lists the entire table of community strings, which could allow attackers to conduct unauthorized activities.
Vulnerability data from NVD (NIST) · CISA KEV · EPSS

